OD MODEL
4TWR4024G1

ID MODEL
GAF2A0A18S11+TDR

NOM CFM
740

ARI REF #
8931998

Published Date: 12/07/2022

COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES

OD AMB
ID WBTOT CAP72757880KW
85
5921.6017.4019.521.6021.601.64
6322.7014.3016.418.4019.801.66
6724.2011.3013.415.4016.801.67
7126.308.4010.512.6014.001.69
95
5920.7017.0019.120.7020.701.90
6321.7013.9015.918.0019.401.92
6723.2010.9013.015.1016.501.93
7125.108.0010.112.2013.601.95
105
5919.7016.5018.619.7019.702.15
6320.7013.4015.517.6019.002.17
6722.1010.5012.614.6016.002.19
7124.007.609.711.8013.202.21
115
5918.8016.1018.218.8018.802.41
6319.7013.0015.117.2018.602.43
6721.0010.1012.114.2015.602.45
7122.807.209.311.4012.802.48

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

AIR FLOW RATE, CFM.CAPACITY MULTIPLIERTOTAL POWER MULTIPLIER
6500.980.99
8251.021.01

ARI RATING FOR COOLING

CFMCAPACITY (A) TESTSEEREER
6502260014.0011.50

A.R.I. Standard Capacity Rating Conditions

A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.

 

 

 

 

OD MODEL
4TWR4024G1

ID MODEL
GAF2A0A18S11+TDR

NOM CFM
800

ARI REF #
8931998

Published Date: 12/07/2022

HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE

 TOTAL CAPACITY MBH.TOTAL POWER IN KILOWATTS
OD AMB6070758060707580
211.0010.8010.7010.601.631.711.751.79
712.4012.2012.1012.001.651.731.771.81
1213.8013.6013.4013.301.671.751.791.84
1715.2014.9014.8014.601.691.771.821.86
2216.0015.7015.6015.401.701.791.831.87
2716.9016.5016.4016.201.711.801.841.89
3217.7017.3017.2017.001.721.811.851.90
3719.1018.7018.5018.401.741.831.881.92
4221.3020.9020.7020.501.781.871.921.96
4723.5023.1022.9022.601.811.911.962.00
5224.9024.4024.2024.001.841.931.982.03
5726.3025.8025.6025.301.861.952.002.05
6227.7027.2026.9026.601.881.982.022.07
6729.1028.5028.3028.001.902.002.052.10
7230.5029.9029.6029.301.922.022.072.12

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

AIR FLOW RATE, CFM.CAPACITY MULTIPLIERTOTAL POWER MULTIPLIER
7000.990.98
9001.011.03

ARI RATING FOR HEATING

CFMCAPACITY 47COP 47CAPACITY 17COP 17HSPF
650226003.60146002.508.50

A.R.I. Standard Capacity Rating Conditions

A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.