OD MODEL
4TWR5049E1

ID MODEL
4MXCC009AC6HCA

FURNACE
TUH1C100A9H4

NOM CFM
1400

ARI REF #
8975156

Published Date: 12/07/2022

COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES

OD AMB
ID WBTOT CAP72757880KW
85
5943.735.5340.243.743.73.65
6346.428.9333.638.1941.283.66
6749.322.2726.931.5234.613.66
7152.315.520.224.7427.833.68
95
5941.234.2939.041.241.24.03
6343.927.7832.537.0440.134.04
6746.721.1625.830.4133.54.06
7149.614.4319.123.6726.764.08
105
5938.733.0737.538.738.74.46
6341.226.5531.235.8138.94.48
6743.919.9624.629.2132.34.5
7146.713.2718.022.5425.624.53
115
5935.931.7235.435.935.94.95
6338.325.2529.934.5137.64.98
6740.818.6623.327.9231.015
7143.512.0416.721.2924.385.04

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

AIR FLOW RATE, CFM.CAPACITY MULTIPLIERTOTAL POWER MULTIPLIER
12250.980.99
15751.021.01

ARI RATING FOR COOLING

CFMCAPACITY (A) TESTSEEREER
14004600014.0011.50

A.R.I. Standard Capacity Rating Conditions

A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.

 

 

 

 

OD MODEL
4TWR5049E1

ID MODEL
4MXCC009AC6HCA

FURNACE
TUH1C100A9H4

NOM CFM
1400

ARI REF #
8975156

Published Date: 12/07/2022

HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE

 TOTAL CAPACITY MBH.TOTAL POWER IN KILOWATTS
OD AMB6070758060707580
220.4219.8720.0519.693.113.243.33.36
722.7322.1222.3221.923.173.33.373.44
1225.0824.424.6324.183.233.373.443.51
1727.492726.7526.513.33.443.513.58
2229.829.2528.9728.693.343.493.563.63
2732.131.4931.1930.883.393.543.613.69
3233.9533.2832.9532.613.433.593.663.74
3737.1836.4536.0835.723.523.673.753.83
4241.7840.9940.640.213.63.763.843.92
4746.854645.5845.153.683.853.934.02
5250.0749.1748.7148.263.753.9244.09
5753.352.3351.8551.373.813.994.074.16
6256.5255.554.9954.483.884.064.144.23
6759.7558.6758.1357.593.944.124.214.31
7262.9761.8361.2660.6944.194.294.38

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

AIR FLOW RATE, CFM.CAPACITY MULTIPLIERTOTAL POWER MULTIPLIER
12250.990.98
15751.011.03

ARI RATING FOR HEATING

CFMCAPACITY 47COP 47CAPACITY 17COP 17HSPF
1225455003.5268002.38.2

A.R.I. Standard Capacity Rating Conditions

A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.